Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Diagnostics (Basel) ; 13(17)2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37685359

RESUMO

This study aimed to compare the image quality and diagnostic accuracy of deep-learning-based image denoising reconstructions (DLIDs) to established iterative reconstructed algorithms in low-dose computed tomography (LDCT) of patients with suspected urolithiasis. LDCTs (CTDIvol, 2 mGy) of 76 patients (age: 40.3 ± 5.2 years, M/W: 51/25) with suspected urolithiasis were retrospectively included. Filtered-back projection (FBP), hybrid iterative and model-based iterative reconstruction (HIR/MBIR, respectively) were reconstructed. FBP images were processed using a Food and Drug Administration (FDA)-approved DLID. ROIs were placed in renal parenchyma, fat, muscle and urinary bladder. Signal- and contrast-to-noise ratios (SNR/CNR, respectively) were calculated. Two radiologists evaluated image quality on five-point Likert scales and urinary stones. The results showed a progressive decrease in image noise from FBP, HIR and DLID to MBIR with significant differences between each method (p < 0.05). SNR and CNR were comparable between MBIR and DLID, while it was significantly lower in HIR followed by FBP (e.g., SNR: 1.5 ± 0.3; 1.4 ± 0.4; 1.0 ± 0.3; 0.7 ± 0.2, p < 0.05). Subjective analysis confirmed best image quality in MBIR, followed by DLID and HIR, both being superior to FBP (p < 0.05). Diagnostic accuracy for urinary stone detection was best using MBIR (0.94), lowest using FBP (0.84) and comparable between DLID (0.90) and HIR (0.90). Stone size measurements were consistent between all reconstructions and showed excellent correlation (r2 = 0.958-0.975). In conclusion, MBIR yielded the highest image quality and diagnostic accuracy, with DLID producing better results than HIR and FBP in image quality and matching HIR in diagnostic precision.

2.
Clin Imaging ; 100: 36-41, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37196503

RESUMO

BACKGROUND: Left atrial outpouching structures such as left atrial diverticula (LADs) and left-sided septal pouches (LSSPs) might be a source of cryptogenic stroke. This imaging study evaluates the association between pouch morphology, patient comorbidities and ischemic brain lesions (IBLs). METHODS: This is a retrospective single-center analysis of 195 patients who received both a cardiac CT and a cerebral MRI. LADs, LSSPs, and IBLs were retrospectively identified. Size measurements included pouch width, length and volume for LADs and circumference, area and volume for LSSPs. The association between LADs/LSSPs, IBLs and cardiovascular comorbidities was determined by univariate and bivariate regression analyses. RESULTS: The prevalence and mean volume were 36.4% and 372 ± 569 mm3 for LSSPs, and 40.5% and 415 ± 541 mm3 for LADs. The IBL prevalence was 67.6% in the LSSP group and 48.1% in the LAD group. LSSPs had 2.9-fold increased hazards of IBLs (95%CI: 1.2-7.4, p = 0.024), and LADs showed no significant correlation with IBLs. Size measurements had no impact on IBLs. A co-existing LSSP was associated with an increased prevalence of IBLs in patients with coronary artery disease (HR: 1.5, 95%CI: 1.1-1.9, p = 0.048), heart failure (HR: 3.7, 95%CI: 1.1-14.6, p = 0.032), arterial hypertension (HR: 1.9, 95%CI: 1.1-3.3, p = 0.017), and hyperlipidemia (HR: 2.2, 95%CI: 1.1-4.4, p = 0.018). CONCLUSION: Co-existing LSSPs were associated with IBLs in patients with cardiovascular risk factors, however, pouch morphology did not correlate with the IBL rate. Upon confirmation by further studies, these findings might be considered in the treatment, risk stratification, and stroke prophylaxis of these patients.


Assuntos
Fibrilação Atrial , Doenças Cardiovasculares , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Fibrilação Atrial/complicações , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/epidemiologia , Fatores de Risco , Fatores de Risco de Doenças Cardíacas , Encéfalo
3.
PLoS One ; 17(10): e0276369, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36301863

RESUMO

OBJECTIVE: The aim of this study was to investigate the impact of left atrial diverticula (LADs), left sided septal pouches (LSSPs) and middle right pulmonary veins (MRPVs) on recurrent atrial fibrillation (rAF) in patients undergoing laser pulmonary vein isolation procedure (PVI). MATERIAL AND METHODS: This retrospective study enrolled 139 patients with pre-procedural multiple detector computed tomography (MDCT) imaging and 12 months follow-up examination. LADs, LSSPs and MRPV were identified by two radiologists on a dedicated workstation using multiplanar reconstructions and volume rendering technique. Univariate and bivariate regression analyses with patient demographics and cardiovascular risk factors as covariates were performed to reveal independent factors associated with rAF. RESULTS: LADs were recorded in 41 patients (29%), LSSPs in 20 (14%) and MRPVs in 15 (11%). The right anterosuperior wall of the left atrium was the most prevalent location of LADs (68%). rAF occured in 20 patients, thereof, 15 exhibited an outpouching structure of the left atrium (LAD: 9, LSSP: 2 and MRPV: 3). Presence of an LAD (HR: 2.7, 95%CI: 1.0-8.4, p = 0.04) and permanent AF (HR: 4.8, 95%CI: 1.5-16.3, p = 0.01) were independently associated with rAF. CONCLUSIONS: LAD, LSSP and MRPV were common findings on pre-procedural cardiac computed tomography. LADs were revealed as potential independent risk factor of rAF, which might be considered for treatment planning and post-treatment observation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Divertículo , Veias Pulmonares , Humanos , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia
4.
Diagnostics (Basel) ; 12(3)2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35328224

RESUMO

Virtual non-calcium (VNCa) images from dual-energy computed tomography (DECT) have shown high potential to diagnose bone marrow disease of the spine, which is frequently disguised by dense trabecular bone on conventional CT. In this study, we aimed to define reference values for VNCa bone marrow images of the spine in a large-scale cohort of healthy individuals. DECT was performed after resection of a malignant skin tumor without evidence of metastatic disease. Image analysis was fully automated and did not require specific user interaction. The thoracolumbar spine was segmented by a pretrained convolutional neuronal network. Volumetric VNCa data of the spine's bone marrow space were processed using the maximum, medium, and low calcium suppression indices. Histograms of VNCa attenuation were created for each exam and suppression setting. We included 500 exams of 168 individuals (88 female, patient age 61.0 ± 15.9). A total of 8298 vertebrae were segmented. The attenuation histograms' overlap of two consecutive exams, as a measure for intraindividual consistency, yielded a median of 0.93 (IQR: 0.88-0.96). As our main result, we provide the age- and sex-specific bone marrow attenuation profiles of a large-scale cohort of individuals with healthy trabecular bone structure as a reference for future studies. We conclude that artificial-intelligence-supported, fully automated volumetric assessment is an intraindividually robust method to image the spine's bone marrow using VNCa data from DECT.

5.
Eur J Radiol ; 145: 110037, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34808580

RESUMO

PURPOSE: To investigate the diagnostic value of spectral detector CT (SDCT)-derived virtual non-contrast (VNC), virtual monoenergetic images (VMI) and iodine overlays (IO) for distinguishing infected from noninfected fluid collections (FC) in the chest or abdomen. METHOD: This retrospective study included 58 patients with venous phase SDCT with 77 FC. For all included FC, microbiological analysis of aspirated fluid served as reference. For quantitative analysis, wall thickness was measured, and (ROI)-based analysis performed within the fluid, the FC's wall (if any) and the aorta. Two radiologists qualitatively evaluated visibility of wall enhancement, diagnostic confidence regarding infection of fluid collection, confidence of CT-guided drainage catheter placement and visibility of anatomical landmarks in conventional images (CI) and VNC, VMI40keV, IO. RESULTS: Wall thickness significantly differed between infected (n = 46) and noninfected (n = 31) FC (3.5 ± 1.8 mm vs. 1.4 ± 1.8 mm, AUC = 0.81; p < 0.05). Fluid attenuation and wall enhancement was significantly higher in infected as compared to noninfected FC in all reconstructions (p < 0.05, respectively). Highest AUC regarding A) attenuation in fluid was yielded in CI and VMI70,80keV (0.75); B) wall enhancement in CI (0.88) followed by iodine concentration (0.86). Contrast-to-noise ratio of wall vs. fluid was highest in VMI40keV (p < 0.05). All assessed qualitative parameters received significantly higher ratings when using spectral reconstructions vs. CI (p for all <0.05), except for visibility of wall enhancement. CONCLUSION: Spectral reconstructions improve the assessment of infected from noninfected thoracoabdominal fluid collections and depiction of wall enhancement. Diagnostic performance of the quantitative measurements in spectral reconstructions were comparable with measurements in conventional images.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Abdome , Drenagem , Humanos , Estudos Retrospectivos , Razão Sinal-Ruído
6.
Quant Imaging Med Surg ; 11(8): 3408-3417, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34341719

RESUMO

BACKGROUND: Increased vessel contrast in low-keV virtual monoenergetic images (VMI) in spectral detector CT angiography of the head and neck requires adaption of window settings. Aim of this study was to define generally applicable window settings of low-keV VMI. METHODS: Two radiologists determined ideal subjective window settings for VMI40-70 keV in 54 patients. To obtain generally applicable window settings, center and width values were modeled against the attenuation of the internal carotid artery (HUICA). This modeling was performed with and without respect to keV. Subsequently, image quality of VMI40-70 keV was assessed using the model-based determined window settings. RESULTS: With decreasing keV values, HUICA increased significantly in comparison to conventional images (CI) (P<0.05 for 40-60 keV). No significant differences between modelled and individually recorded window settings were found confirming validity of the obtained models (P values: 0.2-1.0). However, modelling with respect to keV was marginally less precise. CONCLUSIONS: Window settings of low-keV VMI can be semi-automatically determined in dependency of the ICA attenuation in spectral detector CTA of the head and neck. The reported models are a promising tool to leverage the improved image quality of these images in clinical routine.

7.
Sci Rep ; 11(1): 16437, 2021 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-34385563

RESUMO

Computed tomography in suspected urolithiasis provides information about the presence, location and size of stones. Particularly stone size is a key parameter in treatment decision; however, data on impact of reformatation and measurement strategies is sparse. This study aimed to investigate the influence of different image reformatations, slice thicknesses and window settings on stone size measurements. Reference stone sizes of 47 kidney stones representative for clinically encountered compositions were measured manually using a digital caliper (Man-M). Afterwards stones were placed in a 3D-printed, semi-anthropomorphic phantom, and scanned using a low dose protocol (CTDIvol 2 mGy). Images were reconstructed using hybrid-iterative and model-based iterative reconstruction algorithms (HIR, MBIR) with different slice thicknesses. Two independent readers measured largest stone diameter on axial (2 mm and 5 mm) and multiplanar reformatations (based upon 0.67 mm reconstructions) using different window settings (soft-tissue and bone). Statistics were conducted using ANOVA ± correction for multiple comparisons. Overall stone size in CT was underestimated compared to Man-M (8.8 ± 2.9 vs. 7.7 ± 2.7 mm, p < 0.05), yet closely correlated (r = 0.70). Reconstruction algorithm and slice thickness did not significantly impact measurements (p > 0.05), while image reformatations and window settings did (p < 0.05). CT measurements using multiplanar reformatation with a bone window setting showed closest agreement with Man-M (8.7 ± 3.1 vs. 8.8 ± 2.9 mm, p < 0.05, r = 0.83). Manual CT-based stone size measurements are most accurate using multiplanar image reformatation with a bone window setting, while measurements on axial planes with different slice thicknesses underestimate true stone size. Therefore, this procedure is recommended when impacting treatment decision.


Assuntos
Cálculos Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Cálculos Renais/patologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
8.
PLoS One ; 16(6): e0252678, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34129650

RESUMO

OBJECTIVES: To investigate whether virtual monoenergetic images (VMI) and iodine maps derived from spectral detector computed tomography (SDCT) improve early assessment of technique efficacy in patients who underwent microwave ablation (MWA) for hepatocellular carcinoma (HCC) in liver cirrhosis. METHODS: This retrospective study comprised 39 patients with 49 HCC lesions treated with MWA. Biphasic SDCT was performed 7.7±4.0 days after ablation. Conventional images (CI), VMI and IM were reconstructed. Signal- and contrast-to-noise ratio (SNR, CNR) in the ablation zone (AZ), hyperemic rim (HR) and liver parenchyma were calculated using regions-of-interest analysis and compared between CI and VMI between 40-100 keV. Iodine concentration and perfusion ratio of HR and residual tumor (RT) were measured. Two readers evaluated subjective contrast of AZ and HR, technique efficacy (complete vs. incomplete ablation) and diagnostic confidence at determining technique efficacy. RESULTS: Attenuation of liver parenchyma, HR and RT, SNR of liver parenchyma and HR, CNR of AZ and HR were significantly higher in low-keV VMI compared to CI (all p<0.05). Iodine concentration and perfusion ratio differed significantly between HR and RT (all p<0.05; e.g. iodine concentration, 1.6±0.5 vs. 2.7±1.3 mg/ml). VMI50keV improved subjective AZ-to-liver contrast, HR-to-liver contrast, visualization of AZ margin and vessels adjacent to AZ compared to CI (all p<0.05). Diagnostic accuracy for detection of incomplete ablation was slightly higher in VMI50keV compared to CI (0.92 vs. 0.89), while diagnostic confidence was significantly higher in VMI50keV (p<0.05). CONCLUSIONS: Spectral detector computed tomography derived low-keV virtual monoenergetic images and iodine maps provide superior early assessment of technique efficacy of MWA in HCC compared to CI.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Micro-Ondas/uso terapêutico , Ablação por Radiofrequência/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Cirrose Hepática/complicações , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
9.
Radiologe ; 61(7): 677-688, 2021 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-34170363

RESUMO

The acute abdomen is a potentially life-threatening condition and requires a rapid diagnosis. After clinical inspection and in cases with unclear ultrasound findings or unclear serious symptoms computed tomography (CT) and in pregnant women and children magnetic resonance imaging (MRI) is usually necessary. This second part of "Imaging in the acute abdomen" focuses on frequent organ specific causes of the gastrointestinal tract and the urogenital system.


Assuntos
Abdome Agudo , Abdome Agudo/diagnóstico por imagem , Abdome Agudo/etiologia , Criança , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Gravidez , Tomografia Computadorizada por Raios X , Sistema Urogenital/diagnóstico por imagem
10.
Radiologe ; 61(5): 497-510, 2021 05.
Artigo em Alemão | MEDLINE | ID: mdl-33860818

RESUMO

The acute abdomen is characterized by acute abdominal pain with defensive muscular tension, can be triggered by a variety of diseases and sometimes represents a life-threatening condition. After clinical inspection, in most cases dedicated imaging should be performed immediately. The frequently causal appendicitis and cholecystitis can mostly be diagnosed with ultrasound. In other cases with unclear ultrasound findings or unclear severe symptoms, computer tomography (CT) is usually necessary without delay. In contrast, magnetic resonance imaging (MRI) is predominantly indicated in pregnant women and children with unclear ultrasound findings. Thus, the radiologist is an important gatekeeper in the diagnostics of acute abdomen. The radiologist should therefore be familiar with the correct imaging indications, the frequent and rare causes as well as the corresponding morphological imaging characteristics.


Assuntos
Abdome Agudo , Abdome Agudo/diagnóstico por imagem , Abdome Agudo/etiologia , Criança , Feminino , Vesícula Biliar/diagnóstico por imagem , Humanos , Fígado , Imageamento por Ressonância Magnética , Pâncreas , Gravidez , Baço , Ultrassonografia
11.
Clin Nucl Med ; 46(4): 303-309, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33443954

RESUMO

PURPOSE: The aims of this study were to evaluate spectral detector CT (SDCT)-derived iodine concentration (IC) of lymph nodes diagnosed as metastatic and benign in prostate-specific membrane antigen (PSMA) PET/CT and to assess its potential use for lymph node assessment in prostate cancer. PATIENTS AND METHODS: Thirty-four prostate cancer patients were retrospectively included: 16 patients with and 18 without lymph node metastases as determined by PSMA PET/CT. Patients underwent PSMA PET/CT as well as portal venous phase abdominal SDCT for clinical cancer follow-up. Only scan pairs with a stable nodal status indicated by constant size as well as comparable prostate-specific antigen (PSA) levels were included. One hundred benign and 96 suspected metastatic lymph nodes were annotated and correlated between SDCT and PSMA PET/CT. Iodine concentration in SDCT-derived iodine maps and SUVmax in ultra-high definition reconstructions from PSMA PET/CT were acquired based on the region of interest. RESULTS: Metastatic lymph nodes as per PSMA PET/CT showed higher IC than nonmetastatic nodes (1.9 ± 0.6 mg/mL vs 1.5 ± 0.5 mg/mL, P < 0.05) resulting in an AUC of 0.72 and sensitivity/specificity of 81.3%/58.5%. The mean short axis diameter of metastatic lymph nodes was larger than that of nonmetastatic nodes (6.9 ± 3.6 mm vs 5.3 ± 1.3 mm; P < 0.05); a size threshold of 1 cm short axis diameter resulted in a sensitivity/specificity of 12.8%/99.0%. There was a significant yet weak positive correlation between SUVmax and IC (rs = 0.25; P < 0.001). CONCLUSIONS: Spectral detector CT-derived IC was increased in lymph nodes diagnosed as metastatic in PSMA PET/CT yet showed considerable data overlap. The correlation between IC and SUVmax was weak, highlighting the role of PSMA PET/CT as important reference imaging modality for detection of lymph node metastases in prostate cancer patients.


Assuntos
Antígenos de Superfície/metabolismo , Glutamato Carboxipeptidase II/metabolismo , Radioisótopos do Iodo/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/metabolismo , Estudos Retrospectivos
12.
Eur Radiol ; 31(4): 2340-2348, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32997173

RESUMO

OBJECTIVES: Dual-energy computed tomography allows for an accurate and reliable quantification of iodine. However, data on physiological distribution of iodine concentration (IC) is still sparse. This study aims to establish guidance for IC in abdominal organs and important anatomical landmarks using a large cohort of individuals without radiological tumor burden. METHODS: Five hundred seventy-one oncologic, portal venous phase dual-layer spectral detector CT studies of the chest and abdomen without tumor burden at time point of imaging confirmed by > 3-month follow-up were included. ROI were placed in parenchymatous organs (n = 25), lymph nodes (n = 6), and vessels (n = 3) with a minimum of two measurements per landmark. ROI were placed on conventional images and pasted to iodine maps to retrieve absolute IC. Normalization to the abdominal aorta was conducted to obtain iodine perfusion ratios. Bivariate regression analysis, t tests, and ANOVA with Tukey-Kramer post hoc test were used for statistical analysis. RESULTS: Absolute IC showed a broad scatter and varied with body mass index, between different age groups and between the sexes in parenchymatous organs, lymph nodes, and vessels (range 0.0 ± 0.0 mg/ml-6.6 ± 1.3 mg/ml). Unlike absolute IC, iodine perfusion ratios did not show dependency on body mass index; however, significant differences between the sexes and age groups persisted, showing a tendency towards decreased perfusion ratios in elderly patients (e.g., liver 18-44 years/≥ 64 years: 0.50 ± 0.11/0.43 ± 0.10, p ≤ 0.05). CONCLUSIONS: Distribution of IC obtained from a large-scale cohort is provided. As significant differences between sexes and age groups were found, this should be taken into account when obtaining quantitative iodine concentrations and applying iodine thresholds. KEY POINTS: • Absolute iodine concentration showed a broad variation and differed between body mass index, age groups, and between the sexes in parenchymatous organs, lymph nodes, and vessels. • The iodine perfusion ratios did not show dependency on body mass index while significant differences between sexes and age groups persisted. • Provided guidance values may serve as reference when aiming to differentiate healthy and abnormal tissue based on iodine perfusion ratios.


Assuntos
Compostos de Iodo , Iodo , Abdome , Adolescente , Adulto , Idoso , Meios de Contraste , Humanos , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
Invest Radiol ; 56(3): 181-187, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32932376

RESUMO

OBJECTIVES: Dual-energy computed tomography (DECT)-derived quantification of iodine concentration (IC) is increasingly used in oncologic imaging to characterize lesions and evaluate treatment response. However, only limited data are available on intraindividual consistency of IC and its variation. This study investigates the longitudinal reproducibility of IC in organs, vessels, and lymph nodes in a large cohort of healthy patients who underwent repetitive DECT imaging. MATERIALS AND METHODS: A total of 159 patients, who underwent a total of 469 repetitive (range, 2-4), clinically indicated portal-venous phase DECT examinations of the chest and abdomen, were retrospectively included. At time of imaging, macroscopic tumor burden was excluded by follow-up imaging (≥3 months). Iodine concentration was measured region of interest-based (N = 43) in parenchymatous organs, vessels, lymph nodes, and connective tissue. Normalization of IC to the aorta and to the trigger delay as obtained from bolus tracking was performed. For statistical analysis, intraclass correlation coefficient and modified variation coefficient (MVC) were used to assess intraindividual agreement of IC and its variation between different time points, respectively. Furthermore, t tests and analysis of variance with Tukey-Kramer post hoc test were used. RESULTS: The mean intraclass correlation coefficient over all regions of interest was good to excellent (0.642-0.936), irrespective of application of normalization or the normalization technique. Overall, MVC ranged from 1.8% to 25.4%, with significantly lower MVC in data normalized to the aorta (5.8% [1.8%-15.8%]) in comparison with the MVC of not normalized data and data normalized to the trigger delay (P < 0.01 and P = 0.04, respectively). CONCLUSIONS: Our study confirms intraindividual, longitudinal variation of DECT-derived IC, which varies among vessels, lymph nodes, organs, and connective tissue, following different perfusion characteristics; normalizing to the aorta seems to improve reproducibility when using a constant contrast media injection protocol.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Abdome/diagnóstico por imagem , Meios de Contraste , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
14.
Eur J Radiol ; 132: 109267, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32949914

RESUMO

PURPOSE: Computed tomography (CT) is routinely used to assess suspected urolithiasis. Information obtained from CT include presence, location and size of stones, with the latter frequently determining treatment strategy. While there is consensus regarding measurements procedures of kidney stones, influence of radiation dose and reconstruction techniques on stone measurements are unknown. The purpose of this study was to systematically evaluate the influence of these technical determinants on kidney stone size measurements. METHOD: 47 kidney stones of different composition were scanned using a 64-row-multi-detector CT in a 3D-printed, semi-anthropomorphic phantom. Reference stone sizes were measured manually with a digital caliper (Man-M). Stones were imaged with 2 and 10 mGy CTDI. Images were reconstructed using filtered-back-projection, hybrid-iterative and model-based-iterative reconstruction algorithms (FBP, HIR, MBIR) in combination with different kernels and denoising levels. All stones underwent semi-automatic, threshold-based segmentation for computation of maximum diameter and volume. Statistics were conducted using ANOVA ±â€¯correction for multiple comparisons. RESULTS: Overall stone size as compared to manual measurements was overestimated in CT (10.0 ±â€¯3.1 vs. 8.8 ±â€¯2.9 mm, p < 0.05) yet showing a good correlation (R2 = 0.66). Radiation dose and denoising levels did not significantly influence measurements (p > 0.05). MBIR and sharp kernels showed closest agreement with Man-M (9.3 ±â€¯3.1 vs. 8.8 ±â€¯2.9 mm, p < 0.05). Differences within single stones were as high as 40 % (e.g. Man-M: 5.9 mm, CT: 7.3-12.0 mm). CONCLUSIONS: CT-based measurements of kidney stone size appear unaffected by radiation dose and denoising technique, whereas reconstruction algorithms and kernels demonstrate a relevant impact on size measurements. Smallest differences were found using MBIR with a sharp kernel.


Assuntos
Cálculos Renais , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Cálculos Renais/diagnóstico por imagem , Masculino , Imagens de Fantasmas , Doses de Radiação
15.
Eur J Radiol ; 130: 109153, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32717577

RESUMO

PURPOSE: Aim of this study was to develop and evaluate a software toolkit, which allows for a fully automated body composition analysis in contrast enhanced abdominal computed tomography leveraging the strengths of both, quantitative information from dual energy computed tomography and simple detection and segmentation tasks performed by deep convolutional neuronal networks (DCNN). METHODS AND MATERIALS: Both, public and private datasets were used to train and validate DCNN. A combination of two DCNN and quantitative thresholding was used to classify axial CT slices to the abdominal region, classify voxels as fat and muscle and to differentiate between subcutaneous and visceral fat. For validation, patients undergoing repetitive examination (±21 days) and patients who underwent concurrent bioelectrical impedance analysis (BIA) were analyzed. Concordance correlation coefficient (CCC), linear regression and Bland-Altman-Analysis were used as statistical tests. RESULTS: Results provided from the algorithm toolkit were visually validated. The automated classifier was able to extract slices of interest from the full body scans with an accuracy of 98.7 %. DCNN-based segmentation for subcutaneous fat reached a mean dice similarity coefficient of 0.95. CCCs were 0.99 for both muscle and subcutaneous fat and 0.98 for visceral fat in patients undergoing repetitive examinations (n = 48). Further linear regression and Bland-Altman-Analyses suggested good agreement (r2:0.67-0.88) between the software toolkit and patients who underwent concurrent BIA (n = 39). CONCLUSION: We describe a software toolkit allowing for an accurate analysis of body composition utilizing a combination of DCNN- and threshold-based segmentations from spectral detector computed tomography.


Assuntos
Composição Corporal , Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Feminino , Humanos , Gordura Intra-Abdominal/anatomia & histologia , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/anatomia & histologia , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Gordura Subcutânea/anatomia & histologia
16.
Br J Radiol ; 93(1109): 20190992, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32101453

RESUMO

OBJECTIVE: To evaluate phantomless assessment of volumetric bone mineral density (vBMD) based on virtual non-contrast images of arterial (VNCa) and venous phase (VNCv) derived from spectral detector CT in comparison to true non-contrast (TNC) images and adjusted venous phase conventional images (CIV(adjusted)). METHODS: 104 consecutive patients who underwent triphasic spectral detector CT between January 2018 and April 2019 were retrospectively included. TNC, VNCa, VNCv and venous phase images (CIV) were reconstructed. vBMD was obtained by two radiologists using an FDA/CE-cleared software. Average vBMD of the first three lumbar vertebrae was determined in each reconstruction; vBMD of CIV was adjusted for contrast enhancement as suggested earlier. RESULTS: vBMD values obtained from CIV(adjusted) are comparable to vBMD values derived from TNC images (91.79 ± 36.52 vs 90.16 ± 41.71 mg/cm3, p = 1.00); however, vBMD values derived from VNCa and VNCv (42.20 ± 22.50 and 41.98 ± 23.3 mg/cm3 respectively) were significantly lower as compared to vBMD values from TNC and CIV(adjusted) (all p ≤ 0.01). CONCLUSION: Spectral detector CT-derived virtual non-contrast images systematically underestimate vBMD and therefore should not be used without appropriate adjustments. Adjusted venous phase images provide reliable results and may be utilized for an opportunistic BMD screening in CT examinations. ADVANCES IN KNOWLEDGE: Adjustments of venous phase images facilitate opportunistic assessment of vBMD, while spectral detector CT-derived VNC images systematically underestimate vBMD.


Assuntos
Densidade Óssea/fisiologia , Vértebras Lombares/fisiologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/normas , Realidade Virtual
17.
Lancet Infect Dis ; 19(10): e352-e359, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31182290

RESUMO

In high-income countries, the presentation of tuberculosis is changing, primarily because of migration, and understanding the specific health needs of susceptible populations is becoming increasingly important. Although disseminated tuberculosis is well documented in HIV-positive patients, the disease is poorly described and less expected in HIV-negative individuals. In this Grand Round, we report eight HIV-negative refugees, who presented with extensively disseminated tuberculosis. We discuss the multifactorial causes, such as deprivations during long journeys, precarious living conditions, and the experience of violence, which might add to nutritional factors and chronic disorders, eventually resulting in a state of predisposition to immune deficiency. We also show that disseminated tuberculosis is often difficult to diagnose when pulmonary symptoms are absent. Communication difficulties between refugees and health-care workers are another major hurdle, and every effort should be made to get a valid patient history. This medical history is crucial to guide imaging and other diagnostic procedures to establish a definite diagnosis, which should be confirmed by a positive tuberculosis culture. Because many of these patients are at risk for multidrug-resistant tuberculosis, drug susceptibility testing is imperative to guide therapy. In the absence of treatment guidelines for this entity, clinicians can determine treatment duration according to recommendations provided for extrapulmonary tuberculosis and affected organs. Paradoxical expansion of tuberculous lesions during therapy should be treated with corticosteroids. In many cases, treatment duration must be individualised and might even exceed 12 months.


Assuntos
Antibióticos Antituberculose/uso terapêutico , Infecções por HIV , Mycobacterium tuberculosis/genética , Refugiados , Tuberculose Pulmonar/diagnóstico por imagem , Tuberculose Pulmonar/tratamento farmacológico , Adolescente , Adulto , Antibióticos Antituberculose/administração & dosagem , Etambutol/administração & dosagem , Etambutol/uso terapêutico , Radioisótopos de Flúor , Humanos , Isoniazida/administração & dosagem , Isoniazida/uso terapêutico , Masculino , Testes de Sensibilidade Microbiana , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Pirazinamida/administração & dosagem , Pirazinamida/uso terapêutico , Rifampina/administração & dosagem , Rifampina/uso terapêutico , Resultado do Tratamento , Tuberculose Pulmonar/microbiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...